{"id":242,"date":"2026-10-29T17:35:31","date_gmt":"2026-10-29T15:35:31","guid":{"rendered":"https:\/\/micsig.flyboard-baltic.com\/product\/micsig-oper100-1g\/"},"modified":"2026-10-29T17:35:31","modified_gmt":"2026-10-29T15:35:31","slug":"micsig-oper100-1g","status":"publish","type":"product","link":"https:\/\/micsig.flyboard-baltic.com\/et\/toode\/micsig-oper100-1g\/","title":{"rendered":"Micsig OPER100-1G"},"content":{"rendered":"<div class=\"ms-feat\"><img width=\"600\" height=\"380\" src=\"https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/c8828a99fe5113bf786e998e1c6dd961.png\" class=\"attachment-large size-large\" alt=\"\" decoding=\"async\" loading=\"lazy\" srcset=\"https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/c8828a99fe5113bf786e998e1c6dd961.png 600w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/c8828a99fe5113bf786e998e1c6dd961-300x190.png 300w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/c8828a99fe5113bf786e998e1c6dd961-18x12.png 18w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/c8828a99fe5113bf786e998e1c6dd961-416x263.png 416w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/p>\n<p>The third-generation Micsig SigOFIT\u2122 optical-fiber isolated probe, MOIP Series, offers a bandwidth range from 200 MHz to 1.2 GHz, enabling differential measurements from \u00b10.01 V up to \u00b120 kV. Built on Micsig\u2019s exclusive SigOFIT\u2122 leading technology, MOIP Series delivers an exceptionally high CMRR, reaching up to 128 dB at 100 MHz, with an isolation voltage of up to 85 kV and the minimum noise floor is as low as 0.3 mVrms. It reveals the complete truth of signals across its bandwidth range, serving as the ultimate referee for verifying the fidelity of signals measured by other voltage probes.<\/p>\n<\/div>\n<div class=\"ms-feat\"><img width=\"600\" height=\"380\" src=\"https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/b8ead733fbb4c78ccd43a89d44a344d6.png\" class=\"attachment-large size-large\" alt=\"\" decoding=\"async\" loading=\"lazy\" srcset=\"https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/b8ead733fbb4c78ccd43a89d44a344d6.png 600w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/b8ead733fbb4c78ccd43a89d44a344d6-300x190.png 300w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/b8ead733fbb4c78ccd43a89d44a344d6-18x12.png 18w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/b8ead733fbb4c78ccd43a89d44a344d6-416x263.png 416w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/p>\n<h3>Present True Signal<\/h3>\n<p>The SigOFIT optically isolated probe features an exceptionally high common-mode rejection ratio (CMRR), reaching 122 dB at 200 MHz and still maintaining 106 dB at 1.2 GHz. It serves as the ultimate benchmark for verifying the signal fidelity captured by other voltage probes.<\/p>\n<\/div>\n<div class=\"ms-feat\"><img width=\"600\" height=\"380\" src=\"https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/63f63d47ca4e3750176ef80fdc1e845a.png\" class=\"attachment-large size-large\" alt=\"\" decoding=\"async\" loading=\"lazy\" srcset=\"https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/63f63d47ca4e3750176ef80fdc1e845a.png 600w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/63f63d47ca4e3750176ef80fdc1e845a-300x190.png 300w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/63f63d47ca4e3750176ef80fdc1e845a-18x12.png 18w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/63f63d47ca4e3750176ef80fdc1e845a-416x263.png 416w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/p>\n<h3>Calibration-free During Testing<\/h3>\n<p>Real-time optical power compensation ensures continuous high-fidelity waveform output in complex 24\/7 measurement environments, with no manual calibration required.<\/p>\n<\/div>\n<div class=\"ms-feat\"><img width=\"600\" height=\"380\" src=\"https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/5d060a961acaeaaea7fcbecef0dd6784.png\" class=\"attachment-large size-large\" alt=\"\" decoding=\"async\" loading=\"lazy\" srcset=\"https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/5d060a961acaeaaea7fcbecef0dd6784.png 600w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/5d060a961acaeaaea7fcbecef0dd6784-300x190.png 300w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/5d060a961acaeaaea7fcbecef0dd6784-18x12.png 18w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/5d060a961acaeaaea7fcbecef0dd6784-416x263.png 416w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/p>\n<h3>Highest Accuracy<\/h3>\n<p>As the ultimate referee of signal fidelity, the SigOFIT\u2122 optical-fiber isolated probe delivers the highest measurement accuracy. It offers excellent amplitude\u2013frequency characteristics with DC gain accuracy of \u22641% and a minimum noise floor as low as 0.3 mVrms. With zero drift and gain drift of &lt;1%, it is ready to measure immediately at power-on \u2014 no warm-up, no manual calibration.<\/p>\n<\/div>\n<div class=\"ms-feat\"><img width=\"600\" height=\"380\" src=\"https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/37a903ccbd589d4e81df2dd466bc5c53.png\" class=\"attachment-large size-large\" alt=\"\" decoding=\"async\" loading=\"lazy\" srcset=\"https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/37a903ccbd589d4e81df2dd466bc5c53.png 600w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/37a903ccbd589d4e81df2dd466bc5c53-300x190.png 300w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/37a903ccbd589d4e81df2dd466bc5c53-18x12.png 18w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/37a903ccbd589d4e81df2dd466bc5c53-416x263.png 416w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/p>\n<h3>Best Probe for Third-Gen Semiconductor<\/h3>\n<p>SiC and GaN devices can switch high voltages within a few nanoseconds, and their signals may contain high-energy, high-frequency harmonics. Even at the highest bandwidth, the SigOFIT\u2122 probe still delivers nearly 100 dB of CMRR, effectively suppressing the ringing caused by high-frequency common-mode noise and leaving no redundant components. It is the best choice for third-generation semiconductor test and measurement.<\/p>\n<\/div>\n<div class=\"ms-feat\"><img width=\"600\" height=\"380\" src=\"https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/0361d7d9da7d3f79912548fbf6f608a3.png\" class=\"attachment-large size-large\" alt=\"\" decoding=\"async\" loading=\"lazy\" srcset=\"https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/0361d7d9da7d3f79912548fbf6f608a3.png 600w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/0361d7d9da7d3f79912548fbf6f608a3-300x190.png 300w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/0361d7d9da7d3f79912548fbf6f608a3-18x12.png 18w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/0361d7d9da7d3f79912548fbf6f608a3-416x263.png 416w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/p>\n<h3>Safe to Test GaN<\/h3>\n<p>The SigOFIT\u2122 probe features short test leads and coaxial transmission, with input capacitance as low as 1 pF, making it very safe for testing GaN devices.<\/p>\n<\/div>\n<div class=\"ms-feat\"><img width=\"600\" height=\"380\" src=\"https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/e3dfd946fe2a3b40a86cdec8591f2b75.png\" class=\"attachment-large size-large\" alt=\"\" decoding=\"async\" loading=\"lazy\" srcset=\"https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/e3dfd946fe2a3b40a86cdec8591f2b75.png 600w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/e3dfd946fe2a3b40a86cdec8591f2b75-300x190.png 300w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/e3dfd946fe2a3b40a86cdec8591f2b75-18x12.png 18w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/e3dfd946fe2a3b40a86cdec8591f2b75-416x263.png 416w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/p>\n<h3>Real Optical Isolation Technology<\/h3>\n<p>Lasers transmit both the signal and the power over fiber \u2014 no batteries are needed, so the power supply is cleaner \u2014 enabling continuous 24\/7 testing.<\/p>\n<\/div>\n<div class=\"ms-feat\"><img width=\"600\" height=\"380\" src=\"https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/58a041111e691c8fa44431f44156d855.png\" class=\"attachment-large size-large\" alt=\"\" decoding=\"async\" loading=\"lazy\" srcset=\"https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/58a041111e691c8fa44431f44156d855.png 600w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/58a041111e691c8fa44431f44156d855-300x190.png 300w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/58a041111e691c8fa44431f44156d855-18x12.png 18w, https:\/\/micsig.flyboard-baltic.com\/wp-content\/uploads\/2026\/10\/58a041111e691c8fa44431f44156d855-416x263.png 416w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/p>\n<h3>Wide Measurement Range<\/h3>\n<p>Unlike traditional differential probes, which can only measure high-voltage signals, the SigOFIT\u2122 probe works with a range of attenuator tips to measure differential-mode signals from \u00b10.01 V to \u00b120 kV, achieving full-range output and a very high signal-to-noise ratio.<\/p>\n<\/div>\n<h2>Specifications<\/h2>\n<div class=\"ms-spec\">\n<table data-style=\"style-11\" data-sort=\"sortDisabled\">\n<tbody>\n<tr>\n<td rowspan=\"1\">\n<p>Model<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\" valign=\"null\"><strong>MOIP1200P<\/strong><\/td>\n<td>\n<p>MOIP1000P&nbsp;<\/p>\n<\/td>\n<td>\n<p>MOIP500P<\/p>\n<\/td>\n<td>\n<p>MOIP350P<\/p>\n<\/td>\n<td>\n<p>MOIP200P&nbsp;<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bandwidth<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\" valign=\"null\">1.2GHz<\/td>\n<td>\n<p>1GHz<\/p>\n<\/td>\n<td>\n<p>500MHz<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>350MHz<\/p>\n<\/td>\n<td>\n<p>200MHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rise Time<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\" valign=\"null\">\u2264350ps<\/td>\n<td>\n<p>\u2264450ps<\/p>\n<\/td>\n<td>\n<p>\u2264800ps<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>\u22641ns<\/p>\n<\/td>\n<td>\n<p>\u22641.5ns<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>CMRR<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\" valign=\"null\">DC: 180dB<br \/>1.2GHz: 106dB<\/td>\n<td>\n<p>DC: 180dB<br \/>1GHz: 108dB<\/p>\n<\/td>\n<td>\n<p>DC: 180dB<br \/>500MHz: 114dB<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>DC: 180dB<br \/>350MHz: 118dB<\/p>\n<\/td>\n<td>\n<p>DC: 180dB<br \/>200MHz: 122dB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Differential Voltage Range<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\" valign=\"null\">\n<p>Optional OP20(MMCX), \u00b110V<\/p>\n<p>Standard OP50(MMCX), \u00b125V<\/p>\n<p>Optional OP100(MMCX), \u00b150V<\/p>\n<p>Optional OP200(MCX), \u00b1100V<\/p>\n<p>Optional OP500(MCX), \u00b1250V<br \/>Optional OP1000(MCX), \u00b1500V<\/p>\n<p>Optional OP2000(MCX), \u00b11000V<\/p>\n<p>Standard OP5000(MCX), \u00b12500V<\/p>\n<p>Optional OP10000(LCX), \u00b15000V<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Optional OP20(MMCX), \u00b110V<\/p>\n<p>Standard OP50(MMCX), \u00b125V<\/p>\n<p>Optional OP100(MMCX), \u00b150V<\/p>\n<p>Optional OP200(MCX), \u00b1100V<\/p>\n<p>Optional OP500(MCX), \u00b1250V<br \/>Optional OP1000(MCX), \u00b1500V<\/p>\n<p>Optional OP2000(MCX), \u00b11000V<\/p>\n<p>Standard OP5000(MCX), \u00b12500V<\/p>\n<p>Optional OP10000(LCX), \u00b15000V<\/p>\n<\/td>\n<td rowspan=\"1\">\n<p>Optional OP20(MMCX), \u00b110V<\/p>\n<p>Standard OP50(MMCX), \u00b125V<\/p>\n<p>Optional OP100(MMCX), \u00b150V<\/p>\n<p>Optional OP200(MCX), \u00b1100V<\/p>\n<p>Optional OP500(MCX), \u00b1250V<br \/>Optional OP1000(MCX), \u00b1500V<\/p>\n<p>Optional OP2000(MCX), \u00b11000V<\/p>\n<p>Standard OP5000(MCX), \u00b12500V<\/p>\n<p>Optional OP10000(LCX), \u00b15000V<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Optional OP20(MMCX), \u00b110V<\/p>\n<p>Standard OP50(MMCX), \u00b125V<\/p>\n<p>Optional OP100(MMCX), \u00b150V<\/p>\n<p>Optional OP200(MCX), \u00b1100V<\/p>\n<p>Optional OP500(MCX), \u00b1250V<br \/>Optional OP1000(MCX), \u00b1500V<\/p>\n<p>Optional OP2000(MCX), \u00b11000V<\/p>\n<p>Standard OP5000(MCX), \u00b12500V<\/p>\n<p>Optional OP10000(LCX), \u00b15000V<\/p>\n<\/td>\n<td>\n<p>Optional OP20(MMCX), \u00b110V<\/p>\n<p>Standard OP50(MMCX), \u00b125V<\/p>\n<p>Optional OP100(MMCX), \u00b150V<\/p>\n<p>Optional OP200(MCX), \u00b1100V<\/p>\n<p>Optional OP500(MCX), \u00b1250V<br \/>Optional OP1000(MCX), \u00b1500V<br \/>Optional OP2000(MCX), \u00b11000V<\/p>\n<p>Optional OP5000(MCX), \u00b12500V<\/p>\n<p>Optional OP10000(LCX), \u00b15000V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\" valign=\"null\">&lt;0.45mVrms<\/td>\n<td colspan=\"1\">\n<p>&lt;0.45mVrms<\/p>\n<\/td>\n<td rowspan=\"1\">\n<p>&lt;0.3mVrms<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>&lt;0.3mVrms<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>&lt;0.3mVrms<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DC Gain Accuracy<\/p>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\" valign=\"middle\" align=\"center\">\n<p>1%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Common Mode Voltage Range<\/p>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\" valign=\"middle\" align=\"center\">\n<p>85kVpk<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Interface<\/p>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\" valign=\"middle\" align=\"center\">\n<p>Universal BNC, compatible with all brands of oscilloscopes.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ms-official\">Official Micsig dealer in Estonia \u2014 KanEd O\u00dc. 3-year manufacturer warranty, EU invoice with VAT.<\/p>","protected":false},"excerpt":{"rendered":"<p><strong>SigOFIT Attenuator Tip MMCX, attenuation 100:1, \u00b150 V, compatible with 1 GHz, length 1m<\/strong><\/p>\n<p>Bandwidth\uff1a200MHz-1.2GHz Common Mode Voltage\uff1a85kVpk DC Accuracy\uff1a1% CMRR\uff1aup to 180dB Interface: BNC<\/p>","protected":false},"featured_media":204,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[20],"product_tag":[],"class_list":["post-242","product","type-product","status-publish","has-post-thumbnail","product_cat-optical-isolated-probes-sigofit","first","onbackorder","taxable","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/micsig.flyboard-baltic.com\/et\/wp-json\/wp\/v2\/product\/242","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/micsig.flyboard-baltic.com\/et\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/micsig.flyboard-baltic.com\/et\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/micsig.flyboard-baltic.com\/et\/wp-json\/wp\/v2\/comments?post=242"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/micsig.flyboard-baltic.com\/et\/wp-json\/wp\/v2\/media\/204"}],"wp:attachment":[{"href":"https:\/\/micsig.flyboard-baltic.com\/et\/wp-json\/wp\/v2\/media?parent=242"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/micsig.flyboard-baltic.com\/et\/wp-json\/wp\/v2\/product_brand?post=242"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/micsig.flyboard-baltic.com\/et\/wp-json\/wp\/v2\/product_cat?post=242"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/micsig.flyboard-baltic.com\/et\/wp-json\/wp\/v2\/product_tag?post=242"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}